377 Solid Seal RCU

377 Solid Seal RCU

Rapid Curing, High Solids Polyaspartic

Technical Data Sheet

PRODUCT DESCRIPTION

AmeriCote Solid Seal RCU is a two component, high gloss, polyurea coating designed for industrial and commercial applications. Solid Seal RCU is designed for use as a fast-curing UV stable topcoat. Solid Seal RCU is an excellent topcoat for decorative flake and decorative quartz applications. Solid Seal RCU can be pigmented to many colors.

TYPICAL PROPERTIES AT 70 DEGREES

Compressive Strength (ASTMC-579)………………………………………………10,900 psi
Tensile Strength (ASTMD-638)…………………………………………………….5,000 psi
Flexural Strength (ASTMC- 580)……………………………………………….4,550 psi
Hardness Shore D (ASTM D-2240)………………………………………………60—70
Bond Strength (ASTMD-4541)………………………..……………………………300 psi
Abrasion Resistance (ASTMD-4060)…………………….…….….……………..830 mg

The data shown above reflects typical results based on laboratory testing under controlled conditions. Variations from the data shown may result. Test methods are modified where applicable.

INSTALLATION DATA

Storage Environment…………………………………………..…….Dry area, 65-80 F
Application Temperature, ambient………………………………………………50-80 F
Application Temperature, substrate…………………..Minimum 5 F above dew point
Shelf Life……………………………………………………………………..……6 months
Pot Life, @ 77F………………………………………………..……………..13 minutes
Foot Traffic, @ 77F…………………………….……………………………….…3 hours
Full Service, @ 77F………………………………………………….…………24 hours
Recoat Window…………………………………………………within 24 hours at 70F

BENEFITS

  • Multiple system possibilities with one product
    – Full Gloss Finish
    – Multi-color quartz and flake finishes
    – Various surface finishes available
    – Can be used as a base coat or topcoat
  • Seamless, monolithic application
  • Durable finish, chemical resistant
  • Available in clear & a wide array of colors
  • Zero VOC, very low odor

RECOMMENDED USES

  • Warehouse & manufacturing facilities
  • Chemical processing plants
  • Laboratories, hospitals, healthcare facilities
  • Stadiums & other entertainment venues
  • Educational & institutional facilities
  • Cafeterias, kitchens, storefronts, aisles
  • Bathrooms, showers
  • Topcoat over AmeriCote floor systems

GENERIC DESCRIPTION

High Build Polyurea Coating

TYPICAL APPLICATION

Floor Coating (primer plus 2 coats) Aggregate, Color Quartz, or Flake Broadcast Top Coat over AmeriCote Systems

SURFACE PREPARATION

Concrete: Apply only to clean, dry and sound concrete substrates that are free of all coatings, sealers, curing compounds, oils, greases, or any other contaminants

  • New concrete should be cured a minimum of 28 days.
  • Concrete that has been contaminated with chemicals or other foreign matter must be neutralized or removed.
  • Remove any laitance or weak surface layers.
  • Concrete should have a minimum surface tensile strength of at least 300 PSI per ASTM D-4541.
  • Surface profile shall be CSP-3 to CSP-5 meeting ICRI (International Concrete Repair Institute) standard guideline #03732 for coating concrete, producing a profile equal to 60-grit sandpaper or coarser. Prepare surface by mechanical means to achieve this desired profile.
  • Moisture vapor transmission should be 3 pounds or less per 1,000 square feet over a 24 hour time period, as confirmed through a calcium chloride test, as per ASTM E-1907. Quantitative relative humidity (RH) testing, ASTM F-2170, should confirm concrete RH results 75%.
  • All surface irregularities, cracks, expansion joints and control joints should be properly addressed prior to application.
  • Outgassing may occur due to the porosity of some concrete surfaces. To reduce the effect of outgassing, the primer and coating should be applied when the temperature of the concrete substrate is dropping. This usually occurs in the evening: however the concrete substrate temperature should be measured with a surface thermometer for verification. Double priming will greatly reduce the effectsof outgassing by additionally filling the pores in the concrete

STANDARD COLORS

Clear. Variety of color packs available

PACKAGING & COVERAGE

10 Gallon Unit
1 Part A : 1/2 Part B
100 sqft/gallon @ 16 mils

SPECIFICATIONS

  1. Mix Ratio 2:1 Resin to Hardener
  2. Prior to the application of Solid Seal RCU, either  prime concrete surface with Starkrete 718 HGHB or AmeriCote AC592 or AC520, or install over a polyurethane system. Do not install Solid Seal RCU directly to concrete. 
  3. If pigmented color is to be used, add pre-mixed color pack to Park A. Add one color pack per 1.5 mixed gallons for all colors.
  4. Pour Part B into the Part A pail and mix for a minimum of two minutes, using a mechanical jiffy-type mixer operated at low speed. Scrape the side of the pail to ensure the entire product has been properly mixed; any unmixed material left on the side of the pail will not cure.
  5. Apply mixed material by roller or squeegee and back-roll. Move quickly and empty eopoxy coating out of the pail and onto concrete surface as quickly as possible to provide maximum working time. Material left in the pail will generate heat and have a reduced pot life